JSHIP PLATFORM SCALE OPERATION MANUAL & FULL CALIBRATION GUIDE

1.      KEYBOARD

1)      ON/OFF:  turns the scale On or Off

2)      MODE:  for switching the weighing units of measure from KG to LB

3)      TARE:  for taring or “Zeroing” the scale

2.      SPECIFICATIONS

1)      Capacity:       120kg  / 265lb

2)      Division Value:  0.1kg  / 0.2lb

3)      Weighing units: kg and lb

4)      Weighing units: The scale will keep the same unit as the last one used when the scale was turned off

5)      Auto Turn Off : There is an auto-off function but it is not turned on by default. If you wish to turn on the auto off feature please follow the directions below.

The auto-off function may not turned on when using the adaptor power.

6)      Power Requirements: 4X1.5V AA batteries, or adaptor power

7)      Working electrical current: 5mA,    10uA when turned off

8)      Operation Temperature: 20℃±15

9)      Weighing tolerance: : <±(1% 1D

3.      FUNCTION

1)      ON / OFF: Be sure the power is connected to the scale (or batteries are properly installed). Press the ON/OFF key to turn the scale ON.  The display will briefly show all segments of the display “88888”, then it will go to 0.0.

2)      Zero tracking: This scale has an auto zero tracking function.

3)      AUTO LOCK (default mode):  set AUTO LOCK after the readings stabilize.  The lock icon will be lighted and the readings will be unlocked in 6 seconds. After the readings remain stable, the readings will be locked with a lighted “lock icon”.The readings will be immediately unlocked when the variation of the weighing value exceeds ±20d.

4)      STABILITY INDICATION: As noted above the scale has an indicator to note when the readings are stable or “locked”.

5)      TARING: When the readings stabilize, press the TARE button and the scale will show ‘0.0’. The TARE function can be used repeatedly. Negative figures will be displayed if the tared weight on the tray is removedcounter weighing. You can remove this negative value by pressing the TARE key again..

6)      MODES: Press the MODE key to change the weighing mode from KG to LB or from LB to KG.

7)      LOW VOLTAGE ALARM: If the scale detects low battery or power voltage the battery symbol will appear on the display

8)      OVERLOAD INDICATION: Display will show “EEEEE” if the weight exceeds the capacity of the scale.  Note that overload may damage the scale and void your warranty. Please do not ever overload this scale.

9)      OFF: Press the ON/OFF key to turn the scale off or auto-off.

 

 

 

ADJUSTING THE AUTO-OFF FUNCTION & CALIBRATION

This scale has an optional auto-off feature.  By default the auto-off feature is not turned on. If you want to turn on the auto off feature please follow these instructions below:

1.      Place the scale on a flat, stable surface.

2.      First press and hold the TARE button, then press and release the ON button (but keep the TARE button depressed).  After about 3 seconds all segments of the display will turn on and you are in programming mode.

3.      The first group of program values will show on the display (305F0). If you wish to adjust the auto-off time, press the TARE key once (the 0 will start flashing), now press the mode key several times to change the “0” to a “9”. This sets the auto-off time to 5 minutes. The entire program value should now show as “395F0”.   Note that the TARE key shifts the blinking digit and the MODE key increases the value of the blinking digit.

4.      Press the ON/OFF button 5 times, “- - 0 - -“ will show on the display temporarily and then the scale will show a random number .

5.      Gently load 40kg standard weight; the displayed inner code increases accordingly and stabilizes later;

Press the “OFF” key again,”C 4 0 0” will be shown at the position of 40kg inner code (20kg for the Jship 130) ,the value of the inner code will be displayed several seconds later.

6.      Add 80kg standard weight; the displayed inner code increases accordingly and 

   stabilizes later;

Press the “OFF” key again,”C 8 0 0” will be shown at the position of 80kg inner code (40kg for the Jship 130),the value of the inner code will be displayed several seconds later.

7.      Add 120kg standard weight; the displayed inner code increases accordingly

    and stabilizes later;

Press the “OFF” key again,”C 1 2 0 0” will be shown at the position of 120kg (60kg for the Jship 130)  inner code, “PASS’”will be displayed several seconds later and the scale will turn itself 

off, meaning the completion of the calibration.

8.      Remove the power from the scale to turn it off (unplug the power and/or remove

   the batteries)

9.      Programming is complete,  re-power the scale and it will now be set to your preferred auto-off time. 

 

DISPLAY DEFINITION

OVERLOAD INDICATION:  Display will show “EEEEE”

EXCEED THE RANGE: Display will show “------” and turn off automatically

EXCEED THE TIME20S: Display will show UNST

LOW VOLTAGE under 5.0v: Display will show the battery indicator

WRONG PROGRAM PARAMETERS E2PROM: Display will show “93C46”